Conventional Smoke Beam Detector

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-SBEAMOperating voltage : 16V~28VDCDebug current : ≤20mAMonitoring current : ≤12mAAlarm current : ≤22mAPower consumption : <3WOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencingProtective area : Maksimum 1400m² (14 x 100m) Optional distance : 25meters with 1 reflector ; AR-CFA-SBEAM-2540meters with 1 reflector ; AR-CFA-SBEAM-4070meters with […]

Conventional Indicator Lamp CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-L-RPT Operating voltage : 18V~28VDC Comm. methode : RS485 Comm. baud rate : 9600bps Comm. distance : 1000m Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Dimension : 190mm x 270mm x 30mm CONTACT Related Product

Conventional Heat Detector LPCB

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-L-HD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Fixed temperature : 57˚C Rate of rise : 7,1˚C / 5s Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:7 Dimension […]

Conventional Smoke Detector LPCB

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-L-SD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Smoke sencivifity : 0,1 ~ 0,15dB/m Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:5 Dimension : ø99,45mm, H : 48,2mm […]

Conventional Smoke Heat Detector CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-C-SHD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Smoke sencitivity : 0,1 ~ 0,15dB/m Fixed temperature : 57˚C Rate of rise : 7,1˚C / 5s Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing […]

Conventional Heat Detector CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-C-HD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Fixed temperature : 57˚C Rate of rise : 7,1˚C / 5s Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:7 Dimension […]

Conventional Smoke Detector CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-C-SD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Smoke sencivifity : 0,1 ~ 0,15dB/m Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:5 Dimension : ø99,45mm, H : 48,2mm […]

Control Panel Conventional CE

FEATURE TECHNICAL PARAMETER CONTACT FEATURE Modularized design, the panel can expend from 1 zoneto 32 zone easly 2 level control mode by a lock 24VDC and 5VDC power supply output FIRE and FAULT signal output 2 General sounders output Each zone has 1 circuit detectors input Each zone can be disable by a button RESET […]

Addressable Annunciator EN

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-AFA-2W-ANNOperating voltage : Loop 24V (18V~28V)Working current : 10 ~ 30mAProgramming range : Occupying one address within 1~250Operating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencing CONTACT Related Product

Addressable Monitor Module EN

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-AFA-2W-MMOperating voltage : Loop 24V (18V~28V)Standby current : ≤5mAAlarm current : ≤25mAProgramming range : Occupying one address within 1~250Operating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencing CONTACT Related Product

Fast Respons Via WA