Conventional Manual Call Point CE
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-MCPOperating voltage : 24VDCMax. current : 8A @ 24VDCContact resistance : ≤0,02 ΩOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencing CONTACT Related Product
Conventional Manual Pull Station CE
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-MPSOperating voltage : 9V~28VAlarm current : 45mA @ 24VDCOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencingDimension : 140mm x 105mm x 45mmWeight : 220g CONTACT Related Product
Conventional Strobe Sounder CE
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-STROBEOperating voltage : 16V~30VDCWorking current : 100mA ~ 150mAFlash intensity : ≥1,2WSFlash period : ≤1,5sAlarm sound : ≥100dBFlash light lifespan : ≥40000 TimeAlarm sound tipe : 3 sound (ambulance, police car, fire truck)Operating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencing CONTACT Related Product
Conventional Alarm Bell CE
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-BELLOperating voltage : 12V ~24VDCWorking current : 50mA @ 24VDCVolume dB :≥96dBOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencingDimension : 6”Weight : 0,9kg CONTACT Related Product
Remote Indicating Lamp CE
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-RILOperating voltage : 24VDCMax. current : 8AContact resistance : ≤0,1ΩOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencingCompatible : Conventiona system CONTACT Related Product
UV Flame Detector EXP
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-EXP-UV-FLAMEOperating voltage : 18V~30VDCMonitoring current : ≤15mAAlarm current : ≤35mADetection : Angle 120˚ Distance 60mWarming up : Energized after 60sAlarm treshold : 1 ~ 5 adjustableAlarm delay : 0 ~ 30sadjustableOutput contact : 1A @ 30VDCIndicators : 3 indicator statusOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, […]
IR2 Flame Detector EXP
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-EXP-IR2-FLAMEOperating voltage : 18V~30VDCMonitoring current : ≤15mAAlarm current : ≤35mADetection : Angle 120˚ Distance 60mWarming up : Energized after 60sAlarm treshold : 1 ~ 5 adjustableAlarm delay : 0 ~ 30sadjustableOutput contact : 1A @ 30VDCIndicators : 3 indicator statusOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, […]
IR3 Flame Detector EXP
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-EXP-IR3-FLAMEOperating voltage : 18V~30VDCMonitoring current : ≤15mAAlarm current : ≤35mADetection : Angle 120˚ Distance 60mWarming up : Energized after 60sAlarm treshold : 1 ~ 5 adjustableAlarm delay : 0 ~ 30sadjustableOutput contact : 1A @ 30VDCIndicators : 3 indicator statusOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, […]
Conventional Smoke Beam Detector
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-SBEAMOperating voltage : 16V~28VDCDebug current : ≤20mAMonitoring current : ≤12mAAlarm current : ≤22mAPower consumption : <3WOperating temperature : -10˚ ~ +55˚CRelative humidity : ≤95%, non condencingProtective area : Maksimum 1400m² (14 x 100m) Optional distance : 25meters with 1 reflector ; AR-CFA-SBEAM-2540meters with 1 reflector ; AR-CFA-SBEAM-4070meters with […]
Conventional Indicator Lamp CE
TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-L-RPT Operating voltage : 18V~28VDC Comm. methode : RS485 Comm. baud rate : 9600bps Comm. distance : 1000m Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Dimension : 190mm x 270mm x 30mm CONTACT Related Product