Conventional Heat Detector LPCB

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-L-HD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Fixed temperature : 57˚C Rate of rise : 7,1˚C / 5s Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:7 Dimension […]

Conventional Smoke Detector LPCB

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-L-SD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Smoke sencivifity : 0,1 ~ 0,15dB/m Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:5 Dimension : ø99,45mm, H : 48,2mm […]

Conventional Smoke Heat Detector CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-C-SHD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Smoke sencitivity : 0,1 ~ 0,15dB/m Fixed temperature : 57˚C Rate of rise : 7,1˚C / 5s Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing […]

Conventional Heat Detector CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-C-HD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Fixed temperature : 57˚C Rate of rise : 7,1˚C / 5s Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:7 Dimension […]

Conventional Smoke Detector CE

TECHNICAL PARAMETER CONTACT TECHNICAL PARAMETER Type : AR-CFA-C-SD Operating voltage : 9V~28VDC non polarized Standby current : ≤120µA @ 24VDC Alarm current : ≤15mA @ 24VDC Smoke sencivifity : 0,1 ~ 0,15dB/m Operating temperature : -10˚ ~ +55˚C Relative humidity : ≤95%, non condencing Standard num. ref. : EN54:5 Dimension : ø99,45mm, H : 48,2mm […]

Control Panel Conventional CE

FEATURE TECHNICAL PARAMETER CONTACT FEATURE Modularized design, the panel can expend from 1 zoneto 32 zone easly 2 level control mode by a lock 24VDC and 5VDC power supply output FIRE and FAULT signal output 2 General sounders output Each zone has 1 circuit detectors input Each zone can be disable by a button RESET […]


Deprecated: usort(): Returning bool from comparison function is deprecated, return an integer less than, equal to, or greater than zero in /home/u7175395/public_html/wp-content/plugins/whatsapp-for-wordpress/includes/nta-whatsapp-popup.php on line 182
Fast Respons Via WA